Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE

Main Features

  • Power Rating: 250 VA
  • Input Receptacles: 1 x NEMA L5-15P
  • Output Receptacles: 2 x NEMA 5-15R
  • Input Voltage: 120 V AC
  • Input Voltage Range: 120 V AC Nominal
  • Output Voltage: 120 V AC Nominal
  • Frequency: 60 Hz
  • Current: 2.10 A
  • Power Cord/Cable: 1.83 m
  • Form Factor: Tower
  • Dimensions: 114 mm Height x 121 mm Width x 197 mm Depth
  • Additional Information:
  • Transformer Type: Medical grade, low impedance transformer-based line isolation transformer
  • Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Suppression Joule Rating: 680 (510 input/170 output)
  • Leakage Current: As low as 100 microamps
  • Noise Suppression Rating: 35 to 65 DB
  • Total Harmonic Distortion: Less than 1%
  • Over Current Protection: 2A circuit breaker
  • Cooling Method: Convection
  • Efficiency: 96%
  • Let-through Voltage (Ring Wave):
    • L-N: 20 V
    • L-G: 20 V
    • N-G: 0.5 V
  • Let-through Voltage (Combination Wave):
    • L-N: 250 V
    • L-G: 250 V
    • N-G: 0.5 V
  • Package Contents:
  • IS250HG
  • IS250HG Isolation Transformer
  • Instruction manual with warranty information
  • Certifications & Standards:
  • cUL
  • UL 2601-1
  • UL (UL Series AGIS250YWN)
  • Standard Warranty: 2 Year Limited
  • Package Contents

  • IS250HG
  • IS250HG Isolation Transformer
  • Instruction manual with warranty information
  • General Information

    Product TypeIsolation Transformer
    Brand NameTripp Lite
    ManufacturerTripp Lite
    Product ModelIS250HG
    Product NameIsolator IS250HG Isolation Transformer
    Manufacturer Part NumberIS250HG
    Manufacturer Website Addresswww.tripplite.com
    Marketing Information

    Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE

    Technical Information

    Power Rating250 VA
    Input Receptacles1 x NEMA L5-15P
    Output Receptacles2 x NEMA 5-15R

    Power Description

    Current2.10 A
    Input Voltage Range120 V AC Nominal
    Frequency60 Hz
    Input Voltage120 V AC
    Output Voltage120 V AC Nominal

    Physical Characteristics

    Form FactorTower
    Power Cord/Cable1.83 m
    Dimensions114 mm Height x 121 mm Width x 197 mm Depth

    Miscellaneous

    Certifications & Standards
  • cUL
  • UL 2601-1
  • UL (UL Series AGIS250YWN)
  • Package Contents
  • IS250HG
  • IS250HG Isolation Transformer
  • Instruction manual with warranty information
  • Additional Information
  • Transformer Type: Medical grade, low impedance transformer-based line isolation transformer
  • Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops
  • Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
  • Suppression Joule Rating: 680 (510 input/170 output)
  • Leakage Current: As low as 100 microamps
  • Noise Suppression Rating: 35 to 65 DB
  • Total Harmonic Distortion: Less than 1%
  • Over Current Protection: 2A circuit breaker
  • Cooling Method: Convection
  • Efficiency: 96%
  • Let-through Voltage (Ring Wave):
    • L-N: 20 V
    • L-G: 20 V
    • N-G: 0.5 V
  • Let-through Voltage (Combination Wave):
    • L-N: 250 V
    • L-G: 250 V
    • N-G: 0.5 V