Description
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE
Main Features
Power Rating: 250 VA
Input Receptacles: 1 x NEMA L5-15P
Output Receptacles: 2 x NEMA 5-15R
Input Voltage: 120 V AC
Input Voltage Range: 120 V AC Nominal
Output Voltage: 120 V AC Nominal
Frequency: 60 Hz
Current: 2.10 A
Power Cord/Cable: 1.83 m
Form Factor: Tower
Dimensions: 114 mm Height x 121 mm Width x 197 mm Depth
Additional Information: Transformer Type: Medical grade, low impedance transformer-based line isolation transformer Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode Suppression Joule Rating: 680 (510 input/170 output) Leakage Current: As low as 100 microamps Noise Suppression Rating: 35 to 65 DB Total Harmonic Distortion: Less than 1% Over Current Protection: 2A circuit breaker Cooling Method: Convection Efficiency: 96% Let-through Voltage (Ring Wave): - L-N: 20 V
- L-G: 20 V
- N-G: 0.5 V
Let-through Voltage (Combination Wave): - L-N: 250 V
- L-G: 250 V
- N-G: 0.5 V
Package Contents: IS250HGIS250HG Isolation TransformerInstruction manual with warranty information
Certifications & Standards: cUL UL 2601-1 UL (UL Series AGIS250YWN)
Standard Warranty: 2 Year Limited
Package Contents
IS250HGIS250HG Isolation TransformerInstruction manual with warranty information