Description
750VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 in. Extended runtime available with optional BP24V15RT2U, BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs. Full-time sine wave 100, 110 or 120V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 138. NEMA 5-15P input plug; NEMA 5-15R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and
Main Features
Plug/Connector Type: NEMA 5-15P
Receptacles: 6 x NEMA 5-15R
Switching Time: 0 ns
Dataline Protection: RJ-45 Dialup Phone/DSL line/Network Ethernet
Load Capacity: 750 VA/600 W
Input Voltage: 110 V AC
Input Voltage Range: 100 V AC
Input Voltage Range: 120 V AC
Output Voltage: 100 V AC Nominal
Output Voltage: 110 V AC Nominal
Output Voltage: 120 V AC Nominal
Frequency: 50 Hz
Frequency: 60 Hz
Voltage Handling: 2% Output
Network Management: SNMP Manageable Optional
Overload Protection: 15A input breaker
Bypass Switch: Automatic
Emergency Power OFF: Yes
Interfaces/Ports: USB
Interfaces/Ports: DB-9 Serial
Batteries: User-replaceable Hot-swappable
Backup/Run Time: 0.07 Hour 600 W Full Load
Backup/Run Time: 0.18 Hour 300 W Half Load
Battery Recharge Time: <6 Hour
Form Factor: 2U Tower/Rack Mountable
Package Contents: SmartOnline Expandable 750VA Tower/Rack Mountable UPS SystemOnline Double-Conversion UPS SystemPowerAlert Software and cablingMounting hardware for 4-post rack enclosuresInstruction manual with warranty information
Additional Information: Switches: Includes power off/on switch to enable system turn on (press on switch), UPS battery test (press on switch during normal AC operation), buzzer silence (press on switch during battery operation) and off (press off switch) - all switch functions require that the switch be pressed and held for longer than 2 seconds, but less than 4 seconds Low voltage transfer to battery power: Maintains continuous operation during undervoltages as low as 65V (80V at load levels over 70%). Below this switchover point, output is supported from battery-derived AC power High voltage transfer to battery power: Maintains continuous operation without using battery power during overvoltages to 138V. Above this point, output is supported from battery-derived AC power Cold Start: Yes, inverter can be "cold started" to enable temporary AC output during a power failure
Certifications & Standards: Tested to UL1778 (USA), CSA (Canada), Class B (EMI)
Software Included: PowerAlert Software
Standard Warranty: 2 Year
Package Contents
SmartOnline Expandable 750VA Tower/Rack Mountable UPS SystemOnline Double-Conversion UPS SystemPowerAlert Software and cablingMounting hardware for 4-post rack enclosuresInstruction manual with warranty information