Description
8000VA (8kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 6 rack spaces (3U power module and 3U battery pack). Maximum installed rack depth of 32.5 in. Expandable battery runtime with optional BP240V10RT3U external battery packs. Full-time sine wave 200, 208, 220, 230, or 240V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V. Includes Hubbell twist-lock 208V 50A input plug for simple installation; NEMA L6-30R and L6-20R output receptacles. Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support communications via RS-232, contact-closure port and optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs offer at-a-glance confirmation of line power status, battery power statu
Main Features
Receptacles: 4 x NEMA L6-20R
Receptacles: 2 x NEMA L6-30R
Load Capacity: 8 kVA/6.40 kW
Input Voltage: 110 V AC
Input Voltage: 220 V AC
Input Voltage Range: 200 V AC
Input Voltage Range: 208 V AC
Input Voltage Range: 220 V AC
Input Voltage Range: 230 V AC
Input Voltage Range: 240 V AC
Output Voltage: 200 V AC Nominal
Output Voltage: 208 V AC Nominal
Output Voltage: 220 V AC Nominal
Output Voltage: 230 V AC Nominal
Output Voltage: 240 V AC Nominal
Frequency: 50 Hz
Frequency: 60 Hz
Voltage Regulation: ±2 Output
Filtering: EMI / RFI
Network Management: SNMP Manageable Optional
Bypass Switch: Manual
Emergency Power OFF: Yes
Interfaces/Ports: 1 x DB-9 RS-232 Serial
Interfaces/Ports: 1 x DB-9
Batteries: User-replaceable Hot-swappable
Backup/Run Time: 0.10 Hour 6.40 kW Full Load
Backup/Run Time: 0.25 Hour 3.20 kW Half Load
Battery Recharge Time: 8 Hour Typical
Form Factor: 6U Tower/Rack Mountable
Dimensions: 131 mm Height x 445 mm Width x 635 mm Depth
Weight (Approximate): 25 kg
Package Contents: SmartOnline SU8000RT3UN50 8kVA Tower/Rack-mountable UPS3U power module with detachable hot-swap PDU input/output panel and bypass switch3U external battery packTwo sets of 4 post rackmount rails (one for each of the 3U components)One set of tower stands for upright tower con
Additional Information: Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection Common applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems Input connection type: Hubbell CS8265C 50A input plug
Software Included: PowerAlert UPS Software
Standard Warranty: 2 Year
Package Contents
SmartOnline SU8000RT3UN50 8kVA Tower/Rack-mountable UPS3U power module with detachable hot-swap PDU input/output panel and bypass switch3U external battery packTwo sets of 4 post rackmount rails (one for each of the 3U components)One set of tower stands for upright tower con